ACIQ Extreme Series 3 Ton 17.4 SEER2 High Efficiency Heat Pump Split System - R454B Inverter - Multi-Positional

ACiQ

ACIQ Extreme Series 3 Ton 17.4 SEER2 High Efficiency Heat Pump Split System - R454B Inverter - Multi-Positional

36000 BTU/h cooling17.4 SEER239000 BTU/h at 5°F1.9 COP at 5°F

Retailer listing · 1 offer collected

HVACDirect$4,399.99

Listed equipment price

In stock when checkedView retailer offer Price observation: 2026-11-06 · USD

SHOP THE SAME EQUIPMENT

Compare retailer prices.

One exact price collected

1 retailer · 1 offer collected. Prices exclude shipping, tax, and installation. Compare the stock, condition, and date for each offer.

Retailer price observations for ACIQ Extreme Series 3 Ton 17.4 SEER2 High Efficiency Heat Pump Split System -…
RetailerListed price & quantityAvailability & conditionObservedShop
HVACDirectStore policies & support $4,399.99Complete systemIn stock when checkedCondition not recordedSource date 2026-11-06View offer

WHAT WE ACTUALLY OBSERVED

Prices have a history.

Observations keep their original source dates and purchase scopes. Historical lows are separate from current availability. Unpriced and configuration-dependent offers are never treated as exact-price lows.

HVACDirect · Complete system · price & stock history

Open to load this exact offer’s dated source observations.

HEATING BEYOND THE HEADLINE RATING

Cold-weather performance.

Outdoor: ACIQ-36-HPD · Indoor: ACIQ-36-AHD · AHRI: 216032249

Heating capacity at 5°F
39,000 BTU/h
Source
COP at 5°F
1.9
Source
Heating capacity at 47°F
37,000 BTU/h
Source
Reported 5°F / 47°F capacity ratio
105.41%
Source

5°F capacity: Maximum · 5°F COP: At maximum output · 47°F capacity: Rated. A minimum operating temperature does not establish delivered heat. Compare capacity modes and test conditions in the source; a reported capacity ratio is not a certification or rebate qualification.

Standards evidence.

No exact-model certification record has been reviewed for this listing in our evidence collection. This does not establish whether the product is certified.

How to verify the model and scope

THE DETAILS THAT MATTER

A clearer look at the specifications.

Published specifications and their source
SpecificationListed valueSource
SEER217.4Exact matched indoor/outdoor system in the EPA certified product dataset.Official product registryReviewed 2026-11-07
RefrigerantR-454BRetailer specificationsReviewed 2026-11-06
Cooling capacity (BTU/h)36000Official product registryReviewed 2026-11-07
HSPF210.3Current EPA exact ACiQ brand record reports10.3. Manufacturer exact-pair submittal reports HSPF2-4=10.2; discrepancy retained, not averaged.Official product registryReviewed 2026-11-07
Matched outdoor modelACIQ-36-HPDOfficial product registryReviewed 2026-11-07
Matched indoor modelACIQ-36-AHDOfficial product registryReviewed 2026-11-07
AHRI reference number216032249Official product registryReviewed 2026-11-07
EER211.7Official product registryReviewed 2026-11-07
Heating capacity at 47°F as reported (BTU/h)37000NEEP heating_capacity_rated_47 for this exact matched system.Official product registryReviewed 2026-11-07
Heating capacity at 17°F as reported (BTU/h)31800EPA reports this temperature point without an explicit maximum/rated capacity-mode qualifier. Do not silently relabel as maximum or rated.Official product registryReviewed 2026-11-07
Heating capacity at 5°F as reported (BTU/h)39000NEEP heating_capacity_max_5 for this exact matched system.Official product registryReviewed 2026-11-07
COP at 5°F as reported1.9NEEP cop_max_5 for this exact matched system.Official product registryReviewed 2026-11-07
ENERGY STAR status in checked sourceYesCurrent EPA certified product record matched to both component models and refrigerant.Official product registryReviewed 2026-11-07
ENERGY STAR Cold Climate designationYesEPA Cold Climate field explicitly Yes. ENERGY STAR certification and its Cold Climate designation are separate.Official product registryReviewed 2026-11-07
HSPF2 climate regionRegion IVManufacturer explicitly labels HSPF2-4.Manufacturer documentationReviewed 2026-11-07
Rated heating capacity at 47°F (BTU/h)37000NEEP identifies the temperature and operating mode in its field name; matched-system record checked November 7, 2026.Official product registryReviewed 2026-11-07
Maximum heating capacity at 5°F (BTU/h)39000Official product registryReviewed 2026-11-07
COP at maximum output at 5°F1.9Official product registryReviewed 2026-11-07
Reported 5°F / 47°F capacity ratio (%)105.41Calculated from this exact NEEP row: maximum capacity at 5°F divided by rated capacity at 47°F. This ratio is not a certification or rebate qualification.Calculated from published specificationsReviewed 2026-11-07
5°F capacity reporting basisMaximumOperating mode explicitly identified by the NEEP source field.Official product registryReviewed 2026-11-07
47°F capacity reporting basisRatedOfficial product registryReviewed 2026-11-07
5°F COP reporting basisAt maximum outputOfficial product registryReviewed 2026-11-07
Exact system verified on NEEP product listYesLive NEEP record matched to the AHRI reference and both exact component models. NEEP listing and ENERGY STAR Cold Climate are separate statuses.Official product registryReviewed 2026-11-07
COP at rated output at 5°F1.9Official product registryReviewed 2026-11-07
HSPF2 · Region V8.6Official product registryReviewed 2026-11-07
Included equipmentComplete systemRetailer specificationsReviewed 2026-11-06
Number of zones1Retailer specificationsReviewed 2026-11-06
Heat pump typeDucted / centralRetailer specificationsReviewed 2026-11-06
Indoor unit styleMulti-position air handlerRetailer specificationsReviewed 2026-11-06
Heating capacity (BTU/h)37000Retailer specificationsReviewed 2026-11-06
Device input voltage (V)230Retailer specificationsReviewed 2026-11-06
Minimum heating operating temperature (°F)-22Retailer specificationsReviewed 2026-11-06
Refrigerant connectionsFlared / professional installRetailer specificationsReviewed 2026-11-06